Biomethane plant without waste heat: how can the digestate be evaporated?

Short answer: a biomethane plant without waste heat can still evaporate its liquid digestate. The electric MVR evaporator runs on electricity alone and treats liquid fractions up to approx. 2.2 % dry solids (DS). For liquid fractions with higher dry solids up to 4.5 % DS, the DV series has been available with a heat pump since 2026. Both produce a nutrient-rich concentrate, distillate for reuse as process water, and the nitrogen as ammonium sulphate solution (ASL) or, on request, aqueous ammonia.
Why do many biomethane plants have no spare heat?
A biomethane plant upgrades the biogas to biomethane and injects it into the gas grid. Often there is no CHP unit on site whose waste heat could run an evaporator. The digester still needs heat, and depending on the method, so does the upgrading: in chemical (amine) scrubbing, the liquid that binds the carbon dioxide is regenerated by heating, according to IEA Bioenergy Task 37. Spare heat for digestate treatment is therefore often not available at these plants.
Why is liquid digestate a cost factor at a biomethane plant?
Without treatment, all of the liquid digestate has to be stored, transported and spread, and every m³ of it costs money. Where digestate contains livestock manure and is spread in a nitrate-vulnerable zone, the EU Nitrates Directive applies: national action programmes set periods in which land application is prohibited, and storage capacity for livestock manure must exceed what is needed for the longest of these periods (Annex III). The national rules set the details.
Then there is ammonia: according to the European Environment Agency, agriculture is responsible for 93 % of ammonia emissions in the EU, including from spreading manure and slurry. The evaporator binds the ammonia as ASL instead of leaving it in the digestate. Evaporation also reduces the volume that has to be stored, transported and spread. How vacuum and MVR evaporation reduce the volume is described in our post Digestate and slurry evaporators: vacuum vs MVR.
Doesn't digestate evaporation always need surplus heat?
Not necessarily. Thermal evaporation with waste heat does: the IEA Bioenergy report Nutrient Recovery by Biogas Digestate Processing (2015) states that evaporating digestate is only interesting for biogas plants where excess heat is available in sufficient amounts. That applies to the DV series in conventional operation with CHP waste heat. Unlike the process described in the report, MKR adds no acid to the digestate; the nitrogen is bound in the vapour scrubber. Without waste heat, there are two routes: electric evaporation with mechanical vapour recompression (MVR) and the DV series with heat pump.
How can digestate be evaporated without waste heat?
The right route depends on the dry solids of the liquid fraction and on the energy available on site. The evaporator is fed not with raw digestate but with the liquid fraction after solid-liquid separation.
Electric MVR evaporator
The MVR series runs on electricity alone. A compressor raises the pressure and temperature of its own vapour, which then heats the main heat exchanger again. No external heat source is needed. Unlike the DV series, the MVR works at atmospheric pressure, not under vacuum.
22.5 l distillate per kWh electrical (approx. 44 Wh per litre), measured for the complete plant
Feed up to approx. 2.2 % DS
Volume reduction up to 90 % on thin liquid fractions
Operating costs from 8 € per m³ feed
Sizes MVR05 to MVR40, up to approx. 4,000 l/h feed per module; several modules in parallel for over 150,000 m³ of feed per year
If the liquid fraction has more than 2.2 % DS, a second separation stage brings the dry solids down, or the DV series with heat pump is an option. The laboratory test shows which route fits your digestate.
DV series with heat pump
The DV series is a thermal multi-stage vacuum evaporator. Under vacuum, water boils well below 100 °C, and the same heat is used across up to four stages. Since 2026 the DV series has also been available with a heat pump, for biomethane plants without waste heat of their own. It treats liquid fractions with higher dry solids up to 4.5 % DS, above the MVR limit of 2.2 % DS. Where some waste heat is available, it runs as a hybrid system; without waste heat, fully electric. Like all DV evaporators, it reduces the volume by around two thirds.
MVR series | DV series with heat pump | |
Energy | electricity only | electricity via heat pump; hybrid with partial waste heat |
Pressure | atmospheric | vacuum |
DS in feed | up to approx. 2.2 % | up to 4.5 % |
Volume reduction | up to 90 % on thin liquid fractions | around two thirds (DV series) |
Nitrogen product | ASL, aqueous ammonia on request | ASL, aqueous ammonia on request |
Technical data for both series are on our page Vacuum and MVR evaporators. For a first recommendation based on your figures, use the evaporator calculator.
What does evaporating digestate produce?
Three products, each with a defined use:
Ammonium sulphate solution (ASL): the ammonia passes with the vapour into an acid vapour scrubber and is bound there as ASL before the vapour condenses. ASL is a liquid mineral fertiliser (pH 5.5 to 6.5). Where the nitrogen comes from livestock manure and the ASL meets the quality criteria, it can count as a RENURE fertiliser in EU Member States that authorise RENURE. On request, we recover the nitrogen as aqueous ammonia instead.
Concentrate: strongly reduced and rich in nutrients, with phosphorus, potassium and organic nitrogen. It can be used as a farm fertiliser.
Distillate: low in ammonium, COD 100 to 150 mg/l, NH4-N expected below 30 mg/l. It is reused as process water. Discharge depends on local limits and usually needs site-specific finishing.
How do I check before investing whether my digestate is suitable?
Every digestate behaves differently in an evaporator. A laboratory test with 2 litres of your sample shows which evaporation ratio your digestate allows, which material the evaporator needs and whether the upstream separation is sufficient. If needed, an in-house trial with up to 4 m³ follows. For liquid fractions up to 2.2 % DS, the MVR test unit is also available for rent and runs continuously on your own digestate at your site.
The measured operating data under Operating data and evidence come from DV evaporators running on CHP waste heat. An electric MVR has been in operation since 2025: an MVR15 at a peat substitute production site in Germany, which evaporates the washing liquid from separated digestate fibres. All plants are listed under References.
Frequently asked questions
Does a biomethane plant need waste heat to evaporate digestate?
No. The electric MVR evaporator runs on electricity alone and produces 22.5 l distillate per kWh electrical, for thin liquid fractions up to approx. 2.2 % DS. The DV series with heat pump also works without waste heat, for liquid fractions up to 4.5 % DS.
Which evaporator suits the liquid digestate of my biomethane plant?
That depends mainly on the dry solids. Up to approx. 2.2 % DS, the MVR series; for liquid fractions with higher dry solids up to 4.5 % DS, the DV series with heat pump. The laboratory test confirms this with your sample.
What are the operating costs?
Operating costs for the MVR series start at 8 € per m³ feed. The exact figure depends mainly on the electricity price, and on the medium, its dry solids and ammonium content. For the DV series with heat pump, we calculate operating costs for each project. Investment costs are not included.
What happens to the nitrogen?
It is bound in the vapour scrubber as ammonium sulphate solution (ASL), a liquid mineral fertiliser. Aqueous ammonia is possible instead on request.
Can the distillate be discharged?
Not as a general rule. The distillate is usually reused as process water. Whether it may be discharged depends on local limits and usually requires site-specific finishing.
Would you like to know which route suits your biomethane plant? Tell us the type of digestate, the annual volume and, if available, an analysis. We will prepare an outline concept with a budget quotation.
Author: Michael Köhnlechner, Managing Director of MKR Cleanwater GmbH, Monheim (LinkedIn)