Digestate storage capacity and slurry storage capacity: how much do you need, and how can you reduce the volume?

Short answer: To calculate digestate storage capacity or slurry storage capacity, start from the longest period in which spreading is not allowed. For livestock manure in nitrate vulnerable zones, the EU Nitrates Directive requires storage for that whole period. The number of months, and whether it also applies to digestate, is set nationally. Germany requires 6 months, or 9 months for operations without their own land or with more than 3 livestock units per hectare. In nitrate vulnerable zones in England, it is 6 months for pig slurry and poultry manure and 5 months for cattle slurry. Rainfall and residual volumes come on top. Evaporating the liquid fraction reduces the volume that is actually stored, transported and spread: by around two thirds with the DV series, or by up to 90 % with the MVR evaporator on thin liquid fractions up to 2.2 % dry solids (DS).
What does EU law require for storage capacity?
Annex III of the Nitrates Directive (91/676/EEC) requires action programmes in nitrate vulnerable zones to set rules on the capacity of storage vessels for livestock manure. This capacity must exceed what is needed to store manure throughout the longest period in which land application is prohibited, unless it can be shown to the authority that any excess will be disposed of without harm to the environment. Each Member State sets how long that period is and whether it also applies to digestate.
How many months of storage do Germany and England require?
Country | Storage period | Applies to |
|---|---|---|
Germany | at least 6 months | liquid manure and digestate from biogas plants (§ 12(2) DüV) |
Germany | 9 months | operations without their own land for spreading, or with more than 3 livestock units per hectare (§ 12(3) DüV, since 1 January 2020) |
England, nitrate vulnerable zones | 6 months (1 October to 1 April) | pig slurry and poultry manure produced in a yard or building |
England, nitrate vulnerable zones | 5 months (1 October to 1 March) | slurry from cattle, sheep, goats, deer and horses |
In Germany, § 12 of the Fertiliser Ordinance (Düngeverordnung, DüV) names digestate from biogas plants explicitly. Rainfall, wastewater, silage effluent and residual volumes that cannot be pumped out must be included. If storage on site is not enough, the operator needs a written contract with a third party for storage or use of the excess.
In England, the rules for nitrate vulnerable zones set the storage periods for slurry and poultry manure. The store must also take rainfall, washings and any other liquid that enters it, and the government guidance asks you to plan for a wetter than average year (1 in 5). Anaerobic digestate is listed as an "other liquid manure"; the guidance sets no storage period of its own for it. The liquid fraction from a slurry separator remains slurry, and the minimum storage must be met without the separator.
How do you calculate digestate storage capacity and slurry storage capacity?
The calculation has the same parts everywhere:
Storage capacity = annual volume of liquid digestate or slurry / 12 months x storage months + rainfall on open stores + residual volume that cannot be pumped out
Worked example (food-waste digestate, Germany): a food-waste biogas plant without its own land produces 40,000 m³ of liquid digestate per year. For 9 months it needs 40,000 m³ / 12 x 9 = 30,000 m³ of storage, plus rainfall and residual volume. This is an example calculation, not a design.
Worked example (pig slurry, England): a pig unit in a nitrate vulnerable zone produces 20,000 m³ of slurry per year. For 6 months it needs 20,000 m³ / 12 x 6 = 10,000 m³ of storage, plus rainfall, washings and residual volume. The minimum must be met without a separator. This is an example calculation, not a design.
How does evaporation reduce the volume of digestate and slurry?
Every cubic metre of water taken out of the liquid fraction does not have to be stored, transported and spread. An evaporator removes water from the liquid fraction and binds the ammonia as ammonium sulphate solution (ASL).
DV series (thermal, under vacuum, on CHP waste heat or with a heat pump): reduces the volume by around two thirds, for liquid fractions up to 4.5 % DS.
MVR evaporator (electric, at atmospheric pressure): reduces the volume by up to 90 % on thin liquid fractions up to 2.2 % DS, such as the liquid fraction of pig slurry after a decanter or separator.
At Reference Plant Western Germany, which treats food-waste digestate, around 3 m³ of digestate becomes around 1 m³ of concentrate. For a plant with 40,000 m³ of liquid digestate per year and 9 months of storage, the volume actually stored would be around 10,000 m³ of concentrate instead of 30,000 m³ of digestate. This is an example calculation based on figures from our website, not a design; how much capacity the authority requires is a separate question. In laboratory tests, the liquid fraction of pig slurry reached evaporation ratios of 1:10 to 1:15.
How much storage capacity the authority requires once a plant evaporates its liquid fraction has to be clarified case by case. In England, the guidance on slurry separators says the minimum storage must be met without the separator; once the legal minimum is met, a separator can further reduce the pressure on the stores. The same question arises for an evaporator and has to be clarified with the authority.
Which evaporator fits which liquid fraction is explained on our page on vacuum and MVR evaporators. The evaporator calculator gives a first recommendation for your figures.
Read more: Digestate and slurry evaporator
What is left to store after evaporation?
Concentrate: highly reduced and nutrient-rich; phosphorus, potassium and organic nitrogen stay in it. It is suitable as farm fertiliser and still needs storage, but much less.
Ammonium sulphate solution (ASL): a liquid mineral fertiliser in its own tank. Under EU law, where the nitrogen comes from livestock manure, such as pig slurry, ASL can count as a RENURE fertiliser, provided it meets the criteria and the Member State authorises RENURE. This does not apply to digestate from food waste alone.
Solids from the separation upstream of the evaporator: a separate stream with its own storage.
Frequently asked questions
How much digestate storage capacity do I need?
Enough for the longest period in which spreading is not allowed. The Nitrates Directive requires this for livestock manure in nitrate vulnerable zones. The months are set nationally: in Germany at least 6 months, or 9 months without own land or with more than 3 livestock units per hectare; in nitrate vulnerable zones in England 6 months for pig slurry and poultry manure and 5 months for cattle slurry. Rainfall and residual volumes come on top.
How do I calculate slurry storage capacity?
Annual volume of liquid slurry or digestate divided by 12, times the storage months, plus rainfall, washings and residual volume. Example calculation, not a design: 20,000 m³ of pig slurry per year and 6 months give 10,000 m³, before rainfall, washings and residual volume.
Does digestate count as slurry for storage rules?
It depends on the country. Germany's Fertiliser Ordinance names digestate from biogas plants explicitly in its storage rule. England's guidance for nitrate vulnerable zones lists anaerobic digestate as an "other liquid manure" and sets no storage period of its own for it.
Does a separator or evaporator reduce the storage I am required to have?
Not automatically. In England, the minimum slurry storage must be met without the separator. Evaporation reduces the volume that is actually stored, transported and spread, by around two thirds with the DV series or up to 90 % with the MVR on thin liquid fractions up to 2.2 % DS. What the authority accepts for your plant has to be clarified case by case.
How can I reduce the volume of digestate or slurry to store?
By evaporating the liquid fraction after separation. A laboratory test with your own sample shows which evaporation ratio your liquid fraction allows.
We are happy to work out with you how much volume is left to store with an evaporator. Send us the type of digestate or slurry, the annual volume and, if available, an analysis.
Author: Michael Köhnlechner, Managing Director of MKR Cleanwater GmbH, Monheim (LinkedIn)
Updated: November 2026
Sources
German Fertiliser Ordinance (Düngeverordnung, DüV), § 12



Comments